| Services Available | |
|---|---|
| Repair | No |
| Free Support | Yes |
The SC-CPI adds CPI bus functionality to your CR800, CR850, CR1000, and CR3000 dataloggers, which is necessary for them to connect to the CDM (Campbell Distributed Module) devices and other CPI-enabled sensors. The SC-CPI connects to the data logger using the C1, C2, and C3 ports.
The SC-CPI is not required for, or supported by, data loggers with a native CPI interface. Campbell Scientific strongly recommends that CDMs be connected to data loggers with a native CPI interface, such as the CR6.
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
| Product | Compatible | Note |
|---|---|---|
| CR1000 (retired) | ||
| CR200X (retired) | ||
| CR206X (retired) | ||
| CR211X (retired) | ||
| CR216X (retired) | ||
| CR295X (retired) | ||
| CR3000 (retired) | ||
| CR800 (retired) | ||
| CR850 (retired) | ||
| CR9000X (retired) |
A 5-conductor cable connects the data logger to the SC-CPI, and an Ethernet cable connects the SC-CPI to the CDM.
The data logger operating system must be version OS 26.
| Temperature Range |
|
| Current Drain | 50 mA (active) |
| Dimensions | 15.94 x 7.49 x 3.18 cm (6.28 x 2.95 x 1.25 in.) including ground lug |
| Weight | 0.188 kg (0.415 lb) |
Connectors |
|
| CPI | RJ45 |
| Serial Connect to Data Logger | Screw terminal |
| Computer Configuration via Device Configuration Utility | USB |
If a download of the full version of purchased software is needed, use the same account made for the purchase and navigate to the account's Purchased Software section.
Execution of this download installs the SC-CPI Operating System on your computer for upload to the SC-CPI device with Device Configuration Utility.
Note: The SC-CPI OS V.02 or greater is required to use the CDM-VW300/305 with the CR3000/1000/800 datalogger that is using OS 28 or higher. The CDM-VW300/305 Operating System will also need to be upgraded to CDM-VW300/305 OS V.02. If using a CR3000/1000/800 datalogger with an older OS, an operating system upgrade to the datalogger will be required.
Number of FAQs related to SC-CPI: 2
To communicate with CDM devices using the CPI protocol, the CR3000, CR1000, CR850, and CR800 dataloggers require an SC-CPI device. Only one SC-CPI device per data logger is required. It is expected that the design of future Campbell Scientific data logger products will work with CPI-based modules directly.
We've updated our privacy policy. Learn More